Shunt Reactors :

These are used to rectify the power factor in electrical power use systems where there are capacitive charges. They can be manufactured as with Air-spaced core, by power as with or without Oil at our firm.



Current Limiting Serial Reactors (Self Coils with or without Iron Core) :
Since Limiting the Short Circuit Current is possible with increasing System Impedance, they are connected to the circuit as serial. These Self Coils manufactured with or without Iron Core can also be manufactured as with or without oil (Dry).

Motor Starting Transformers:
As is known, following certain powers, AC Motors need to be yielded to by means of various methods. One of these is to yield by Transformers. The transformer required for this method with the Three Circuit Breaker application can be manufactured with or without Oil (Dry)

Generator Transformers:
At power stations where Electrical Power is generated, the Transformers to be used for voltage change are of a structure different from normal network transformers of this structure by our firm is within our scope of manufacture.



Rectifier Transformers:

On systems where DC is used, there is equipment that rectifies AC. The transformers that feed this equipment are called Rectifier Transformers They are within the scope of manufacture by our firm.


Earthing Transformers:

On system that do not have a neutral point, these transformers are used for the purpose of creating a grounding point. Thus, if a Phase-Grounding short circuit occurs on the system, the possibility of seeing this will arise.

Star Point Earthing Coils :

On systems with Star Point grounding, in order to limit Star Point short circuit current, some methods are applied. Manufacture of one of them, Grounding Coils appropriate for desired current limiting at Star Point and grounding point, is carried out by our firm.

Dry Type Transformers :
Manufacture of Dry type transformers up to 1600 kVA power and 12 kV system voltage is performed.

Transformers for Testing Purposes (100-420 kV, Mains Frequency ,Single Phase, appropriate for Purpose) :
To perform an insulation test, according to standarts in compliance with system voltage, the test of Applied Voltage needs to be performed. We also manufacture transformers to be used for this purpose. It is also possible to supply the gauging system if required in case of ordering.

Hermetic, Transformers with Plug-in Bushings :
In conformity with technical specifications, manufacture of Hermetic and/or Plug-in(with fitting bushing) Transformers with Bushing is reliably designed and manufacture thereof is performed.

For Example:
Booster Transformers
and Locomotive Transformers.